Operating temp.: -10 °C to 70 °C
Voltage Grade up to:Â 1.1 kV
Requirement of oxygen in air to catch fire:Â more then 29.5%
Temperature required to catch fire (with 21% oxygen): more then 250 °C
Visibility during cable burning:Â less then 30%
“RADIX” copper conductor, PVC insulated and sheathed multicore flexible cables
Size / Area in Sq.mm. | No. & size of wire | Nominal Insulation thickness (mm) | Overall core Diameter (mm) | Sheath thickness (mm) | Overall diameter (mm) | Max. resistance @20°C (ohm/km) | Current rating (Amp.) | ||||
2 core | 3 core | 4 core | 2 core | 3 core | 4 core | ||||||
0.50 | 16/0.20 | 0.60 | 2.20 | 0.90 | 0.90 | 0.90 | 6.20 | 6.60 | 7.20 | 39.00 | 4.00 |
0.75 | 24/0.20 | 0.60 | 2.50 | 0.90 | 0.90 | 0.90 | 6.80 | 7.20 | 7.90 | 26.00 | 7.00 |
1.00 | 32/0.20 | 0.60 | 2.60 | 0.90 | 0.90 | 0.90 | 7.00 | 7.50 | 8.10 | 19.50 | 11.00 |
1.50 | 48/0.20 | 0.60 | 2.90 | 0.90 | 0.90 | 1.00 | 7.60 | 8.10 | 9.00 | 13.30 | 14.00 |
2.50 | 80/0.20 | 0.70 | 3.50 | 1.00 | 1.00 | 1.00 | 9.00 | 9.60 | 10.50 | 7.98 | 19.00 |
4.00 | 56/0.30 | 0.80 | 4.30 | 1.00 | 1.00 | 1.00 | 10.60 | 11.30 | 12.40 | 4.95 | 25.00 |
6.00 | 84/0.30 | 0.80 | 5.50 | 1.30 | 1.30 | 1.40 | 13.70 | 14.00 | 16.50 | 3.30 | 32.00 |
10.00 | 140/0.30 | 1.00 | 6.70 | 1.40 | 1.40 | 1.40 | 16.50 | 18.00 | 19.00 | 1.91 | 45.00 |
16.00 | 224/0.30 | 1.00 | 8.40 | 1.40 | 1.40 | 1.40 | 19.00 | 20.50 | 23.00 | 1.21 | 60.00 |
Note:Â Insulation thickness, sheath thickness and overall dimension given in the table are nominal values. The number of wires and strand diameter are satisfy the requirements of conductor resistance as per IS:8130/1984. As per to IS :694/2010
“RADIX” copper conductor, PVC insulated and sheathed multicore flexible control cables
Size in sq. mm. | Size in mm. | Current Rating | Approximate overall diameter of cable (mm) | ||||||||
5 core | 6 core | 7 core | 8 core | 10 core | 12 core | 14 core | 16 core | 19 core | |||
0.50 | 16/0.20 | 4.00 | 8.30 | 8.50 | 8.50 | 9.30 | 10.80 | 11.20 | 12.00 | 12.60 | 13.20 |
0.75 | 24/0.20 | 7.00 | 9.10 | 9.50 | 9.50 | 10.40 | 12.20 | 12.60 | 13.30 | 14.20 | 14.90 |
1.00 | 32/0.20 | 11.00 | 9.60 | 9.80 | 9.80 | 10.70 | 12.60 | 13.00 | 13.70 | 14.60 | 15.60 |
1.50 | 48/0.20 | 14.00 | 10.30 | 10.70 | 10.70 | 11.90 | 13.80 | 14.30 | 15.20 | 16.00 | 17.10 |
2.50 | 80/0.20 | 19.00 | 11.70 | 12.70 | 12.70 | 14.10 | 16.60 | 17.20 | 18.10 | 19.30 | 20.30 |
4.00 | 56/0.30 | 25.00 | 13.95 | 15.30 | 15.30 | 16.90 | 20.20 | 20.70 | 21.80 | 23.20 | 24.50 |
Note:Â Insulation thickness, sheath thickness and overall dimension given in the table are nominal values. The number of wires and strand diameter are satisfy the requirements of conductor resistance as per IS:8130/1984. As per to IS :694/201